Home > Products&Sevices > Product Showroom > HV Circuit Breaker & Disconnector

detail...
GW4 40.5~252kV Two-column Disconnectors

Application: In rated voltage 40.5~252kV power system, for separating the circuits under off-load status, setup air electrical clearing between the tested electrical apparatuses and electrified circuit.

Ratings: up to 252kV, 3150A

Standards: IEC 62271-102

Click here to download the pdf version catalogue!


detail...
GW22 252kV Vertical Single-column & Single-arm Flexible Fold Type Disconnector

Application: in 252kV power system, for separating the circuits under off-load status ,setup air electrical clearing between the tested electrical apparatuses and electrified circuit.

Ratings: 252kV, 3150A

Standards: IEC 62271-102

Click here to download the pdf version catalogue!


detail...
GW23 252kV Horizontal Single-arm Flexible Fold Type Disconnector

Application: in 252kV power system, for separating the circuits under off-load status ,setup security air electrical clearing between the tested electrical apparatuses and electrified circuit.

Ratings: 252kV, 3150A

Standards: IEC 62271-102

Click here to download the pdf version catalogue!


detail...
LW8 40.5kV SF6 Circuit Breaker

Application: for control and protection of 40.5 kV power system.

Ratings: 40.5kV, 2000A

Standards: IEC 62271-100

Click here to download the pdf version catalogue!


detail...
LW8A SF6 Live Tank Circuit Breaker

Application: for control and protection of 40.5kV power system.

Rated voltage: 40.5kV.                        

Rated current: 2000A.                        

Rated short-circuit breaking current: 31.5kA.

Standards: IEC 62271-100

Click here to download the pdf version catalogue!


detail...
LW36 126kV SF6 Circuit Breaker

Application: for control and protection of 126 kV power system.

Ratings: 126kV, 3150A.

Standards: IEC 62271-100

Click here to download the pdf version catalogue!


detail...
LW43 252kV SF6 Circuit Breaker

Application: for control and protection of 220 kV power system.

Ratings: 252kV, 4000A

Standards: IEC 62271-100

Click here to download the pdf version catalogue!

Category
Power Transformer
Distribution Transformer
Dry Type Transformer
Reactor
GIS (HGIS)
HV Circuit Breaker & Disconnector
Vacuum Circuit Breaker (VCB)
Load Break Switch & Earthing Switch
MV/LV Switchgear Panel & Boxes
HV Surge Arrester & Insulator & Cut-out Fuse
Current Transformer & Potential Transformer
Power Cables & Wires
HV Capacitor & Capacitor Bank
Power Protection & Automation
Distributed Control System (DCS/DEH)
Turn-key Solution
Prefabricated Substation

   
Sitemap  |  Careers  |  Contact Us  |  Privacy Policy ©Copyright 2005-2012 Chint Electric.